翻訳と辞書
Words near each other
・ Concrete Jungle (Black Label Society song)
・ Concrete Jungle (Dive album)
・ Concrete Jungle (Nneka album)
・ Concrete Jungle (Scorcher album)
・ Concrete Jungle (supplement)
・ Concrete Jungle (Sway & King Tech album)
・ Concrete Jungle Vol. 1
・ Concrete landscape curbing
・ Concrete Law
・ Concrete leveling
・ Concrete Love
・ Concrete Marketing
・ Concrete masonry unit
・ Concrete Mathematics
・ Concrete mixer
Concrete moisture meter
・ Concrete Night
・ Concrete number
・ Concrete Pavement Restoration
・ Concrete Pharaohs
・ Concrete plant
・ Concrete Plant Park
・ Concrete poetry
・ Concrete pump
・ Concrete recycling
・ Concrete Revolutio
・ Concrete Roman
・ Concrete Romance
・ Concrete Roots
・ Concrete Rose


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Concrete moisture meter : ウィキペディア英語版
Concrete moisture meter
A concrete moisture meter is a type of moisture meter used by installers of flooring to measure the moisture levels of concrete. These meters have been used for decades to measure the moisture content in different materials and substances. Concrete meters have evolved from the successful wood moisture meter as flooring contractors tried to use their wood meters to measure the moisture in concrete.
Concrete moisture meters are designed to detect moisture to a depth of 1” of a concrete slab in order to avoid the rebar reinforcement below the surface.〔(Why are We Still Having Problems with Moisture? ) ASTM F 2170〕 They are designed to be used as a relative test. 〔(Relative Testing with 'Moisture' Meters )〕 The meters are used to “‘Spot check’ the top surface at one particular location on the slab.” 〔(Concrete Moisture Meters and Calcium Chloride Tests: There Are Better Ways to Test Concrete for Moisture FCI )〕 The results can determine the best place to put a concrete relative humidity test.
==Limitations==
There is no ASTM standard for using a concrete moisture meter to determine a final moisture content reading.
Concrete moisture meters, either non-pin or pin meters are affected by what it sees in the concrete. This can be anything from the density of the concrete and aggregate size to the chemical properties of the slab.
Uncovered concrete dries from the top down. Concrete moisture meters measure only the top inch at most and this area is drier than the concrete further down. Once a floor covering has been installed the moisture in the slab equilibrates. In order to ensure the equilibrated moisture will be a safe level for a floor covering, a relative humidity sensor must be drilled and placed at 40% of the depth of the slab.〔(ASTM F 2170, ”Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes,” ASTM International. )〕 This depth has been proven to be the relative humidity percentage that the slab will equilibrate once the top has been covered by a floor covering.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Concrete moisture meter」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.